Lobeck Medical AG
November 7th, 2008 — admin
Industriestr. 26
5070 Frick
Switzerland
Phone: +41 62 8651150
Fax: +41 62 8651155
http://www.lobeck.com
info@lobeck.com
Manufacturers
Service
Company Contacts
Department/ Name Address
CEO / Mr. Rolf Dornbierer www.lobeck.com
rolf.dornbierer@lobeck.com
Marketing & Sales Manager / Mr. Eric Ballestraz www.lobeck.com
eric.ballestraz@lobeck.com
Company Figures
Export content > 75%
Year of foundation 1979
Area of business Electronical Equipment / Medical Technology
Diagnostics
Commodities and Consumer Goods for Surgeries and Hospitals
Language: German Language: English Company Profile
Lobeck Medical Switzerland
Since it’s foundation in 1979, Lobeck Medical Ltd has concentrated on manufacturing products to the highest possible standard.
The current product strategy is focused on providing practical and easy to use solutions for the diabetic and In-Vitro-Diagnostika markets.
All Lobeck Medical products are sold worldwide under the protected brand name of “Medismart of Switzerland”.
Lobeck Medical’s operations are also fully certified by the auditing bodies of Swiss Medic and TÜV Austria in accordance with ISO9001 and 13485.
The offices of Lobeck Medical are located between Basle and Zurich in the picturesque village of Frick. From there the international airports of Zurich and Basel are only a short 30 minute train journey away.
Product Information
03.01.08 Devices and systems for glucose determination units
03.01.08.01 Blood glucose
MediSmart DIAMOND 25.09.2008
100 test memory
Result in only 5 seconds
Automatically calculation of the 14 day average
Only 1.5µl blood sample required
Easy to read and easy to use
Slim and portable for testing anywhere and anytime
Big measuring range from 33-539 mg/dl
Automatically blood-suck in
Automatically error messaging by to low blood contents
Automatic calibration
Data download for PC possible with USB cable
Link to further Information
MediSmart SAPPHIRE 25.09.2008
480 test memory with dates and time
accurate fast results in only 5 seconds
Automatically calculation of 7, 14 and 28 day average
Only small tiny 0.6µl (microlitres) blood sample required
Measuring range from 20-630 mg/dL (1.1-35 mmol/L)
1 small 3V CR 2032 battery only
Alternative site testing (AST) at palm or forearm possible
Whole blood (capilar or venousblood)
Easy to read with big LCD display and easy to use
Slim and portable device with ergonomic design for testing anywhere and anytime
User friendly handy teststrips with automatically blood-suck in
Automatically error messaging if too low blood contents
Automatic calibration
Datamanagement: download to PC via USB cable (incl. software)
Link to further Information
MediSmart® DIAMOND Set (Starter-Kit) 25.09.2008
1 blood glucose meter Diamond
1 vial with 10 teststrips
1 check-strip
1 code-card
1 lancing device
10 lancettes
2 pcs 1,5 V (AAA) Alkaline batteries
handy travelcase
User Manuals
Quick reference guide with pictures
Logbook
Link to further Information
03.01.08.06 Glucose fully automatic determination
03.01.08.07 Accessories for glucose determination
03.01.08.08 Glucose test strips, biosensors
03.01.14 Rapid tests - clinical chemistry
03.01.14.01 Point of care - testing systems
03.02.15 Rapid tests - Immunochemistry
Colorectal Occult Blood Test 25.09.2008
This testkit helps to save lives all over the world!
The MediSmart colorectal occult blood test is an immunochemical test which also makes it possible for users to test for FOB (Fecal Occult Blood) in the comfort of their own home. The test is extremely accurate (more than 99,5%) and has been designed to detect extremely low levels of human fecal occult blood.
Test results help to determine GI (gastrointestinal) bleedings which are typical for a number of gastrointestinal disorders such as diverticulitis colitis, polyps, and colorectal cancer.
The American Cancer Society and the Centre For Disease Control both recommend an annual FOB test from the age of 50 onwards in order to detect colorectal cancer.
The OMED’s (World Organization for Digestive Endoscopy) Colorectal Cancer Screening Committee recommends immunochemical FOB testing in preference to Guaiac based testing because of the often misleading results of Guaiac tests caused by dietary peroxidases, including haemoglobin and myoglobin from meat and uncooked fruits or vegetables.
Menopause Test 08.09.2008
One step test to predict menopause!
By accurately (over 99%) detecting the levels of FSH (Human Follicular Stimulating Hormone) the MediSmart Menopause Test is able to provide a reliable indication of whether the state of Menopause has been reached or not. The sensitivity is 25mIU/mL.
Ovulation Test 08.09.2008
One step test to determine the fertility status and the best day to conceive a baby!
The MediSmart Ovulation test accurately detects levels of LH (Luteinise Hormone) to ascertain the exact ovulation period via an immunochemical path. This makes it possible for the user to check the regularity of her ovulation period or plan the best time for conception. The sensitivity is 20mIU/mL – more than 99% accuracy.
One testkit contains 5 tests.
03.02.15.01 Pregnancy tests
Pregnancy Test 08.09.2008
The Medismart Early Pregnancy Test has been designed to predict pregnancy only 7 days after sexual intercourse.
How can this be possible?
The MediSmart Early Pregnancy Test uses the highest quality components and measuring processes (membrane, antibody, etc.) to lower the 50 IU HCG (Humanes Choriongonadotropin) cut-off level of most pregnancy testing products down to 20 IU HCG. This major increase in sensitivity makes it possible for the Medismart Early Pregnancy Test to make such early and accurate predictions.
03.02.17 Tumor markers
03.02.17.01 Diagnostic agents / kits for tumour marker determination